{"id":2385,"date":"2026-07-10T14:38:10","date_gmt":"2026-07-10T12:38:10","guid":{"rendered":"https:\/\/localdab.org\/?page_id=2385"},"modified":"2026-10-25T08:27:55","modified_gmt":"2026-10-25T07:27:55","slug":"timetime-and-what-you-need-to-know-about-ittime","status":"publish","type":"page","link":"https:\/\/localdab.org\/index.php\/glossary\/q-t\/timetime-and-what-you-need-to-know-about-ittime\/","title":{"rendered":"Time"},"content":{"rendered":"\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Time (and What You Need to Know About It)Time<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Time plays an essential role in electronic systems, and certainly in the operation of DAB+. A basic understanding of the various time scales is necessary to fully grasp synchronization within a Single Frequency Network (SFN).<br>DAB+ employs various mechanisms to enable this synchronization. Which ones are used depends on the manufacturer\u2019s implementation and the network configuration.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">In this chapter, we discuss the key concepts needed to understand the time references within DAB+.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>The SI-second<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">The SI second is the official unit of time in the International System of Units (SI). It forms the basis of virtually all modern time systems and is essential for applications in which accuracy and synchronization are of great importance.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">The SI second is defined as <strong>9,192,631,770 periods<\/strong> of the radiation corresponding to the transition between two hyperfine energy levels of the ground state of the cesium-133 atom. This extremely stable reference is realized using atomic clocks.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Atomic Time (TAI)<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><strong>TAI (Temps Atomique International)<\/strong> is the international atomic time and is based entirely on the SI second. Unlike UTC, TAI does not include leap seconds, and time passes completely continuously.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><em>PLEASE NOTE:<br>There is an important distinction between TAI and the \u201cTAI-based\u201d time used in the EDI interface. For example, TAI starts counting from <strong>January 1, 1958<\/strong>! The EDI standard for DAB+ makes an important adjustment here and starts on <strong>January 1, 2000<\/strong>!<\/em><\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Within the EDI standard, time is represented as the number of SI seconds that have elapsed <strong>since January 1, 2000, at 00:00:00 TAI. This is therefore not a complete TAI <\/strong>time scale, but a TAI-based time measurement with a fixed reference date.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">This continuous time scale forms the basis for the synchronization of DAB+ stations within an SFN network.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><em>TAI is a fully continuous time scale based exclusively on atomic clocks.<\/em><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>UTC time<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">UTC (Coordinated Universal Time) is the international standard time displayed on our clocks worldwide. As the Earth\u2019s rotational speed is not entirely constant, UTC is adjusted by adding (or, in theory, removing) leap seconds. In this way, UTC remains closely aligned with the Earth\u2019s rotation.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Because of these leap seconds, UTC is less suitable as a time reference for precise synchronisation applications such as a DAB+ SFN. For this reason, a continuous atomic time reference is used for synchronisation.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">However, UTC remains essential for applications where a human-readable date and time format is required, such as log files, error messages and event logging.<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><em>UTC also attempts to keep pace with the Earth\u2019s rotation. When the Earth\u2019s rotation slows slightly, a positive leap second is added to UTC. As a result, UTC always lags slightly behind TAI.<\/em><\/p>\n\n\n\n<div style=\"height:29px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>UTCO (UTC Offset)<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">In order to derive UTC from the TAI-based time, the UTCO (UTC Offset) field is included in EDI messages. This field consists of 8 bits and contains the number of leap seconds that have been introduced since 1 January 2000.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Using this offset, the UTC time can be easily calculated:<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><strong>UTC = TAI-based time \u2212 UTCO<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">The combination of a continuous atomic time and the UTC offset makes it possible, on the one hand, to achieve extremely accurate SFN synchronisation and, on the other hand, to display log files and events in the familiar UTC time.<\/p>\n\n\n\n<div style=\"height:31px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>The leap second is being phased out: what does this mean for DAB+<\/strong>?<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">The 28th General Conference on Weights and Measures (CGPM), which took place in Versailles from 13 to 15 October 2026, took an important decision regarding the future of the leap second. From 20 May 2027, UTC will become a continuous time scale, with no further periodic leap seconds being inserted.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">What impact does this have on DAB+?<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">With DAB+, time information is distributed via the EDI (Encapsulated DAB Interface), which, amongst other things, allows the time to be derived in UTC. The synchronisation of transmitters within a Single Frequency Network (SFN) is based on a continuous, atomic-clock-based time reference and does not depend on the insertion of leap seconds.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">The EDI time information also contains the UTCO (UTC Offset) field, which allows the time scale used to be linked to UTC. An important distinction must be made here: the value of this field is not simply the total number of leap seconds since 1972.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">Once no further leap seconds are inserted from 20 May 2027 onwards, the existing relationship between the EDI time reference and UTC will continue to be maintained. For DAB+ networks that process this time information correctly, this means that the transition itself does not require any change to SFN synchronisation. However, EDI implementations and the associated logging systems must take the new international time regulation into account.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">For the values to be entered in the UTCO field in EDI (UTC Offset), we recommend consulting the EDI implementation manuals and the manufacturer\u2019s implementation documentation. Normally, this should currently be 5 leap seconds.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">The date 20 May 2027 and the transition to continuous UTC are set out in Resolution 5 of the 28th CGPM.<\/p>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><em><a href=\"https:\/\/localdab.org\/index.php\/glossary\/\" data-type=\"page\" data-id=\"15\">Back<\/a><\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Time (and What You Need to Know About It)Time Time plays an essential role in electronic systems, and certainly in the operation of DAB+. A basic understanding of the various time scales is necessary to fully grasp synchronization within a Single Frequency Network (SFN).DAB+ employs various mechanisms to enable this synchronization. Which ones are used [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":1266,"menu_order":79,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-2385","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/localdab.org\/index.php\/wp-json\/wp\/v2\/pages\/2385","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/localdab.org\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/localdab.org\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/localdab.org\/index.php\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/localdab.org\/index.php\/wp-json\/wp\/v2\/comments?post=2385"}],"version-history":[{"count":7,"href":"https:\/\/localdab.org\/index.php\/wp-json\/wp\/v2\/pages\/2385\/revisions"}],"predecessor-version":[{"id":2474,"href":"https:\/\/localdab.org\/index.php\/wp-json\/wp\/v2\/pages\/2385\/revisions\/2474"}],"up":[{"embeddable":true,"href":"https:\/\/localdab.org\/index.php\/wp-json\/wp\/v2\/pages\/1266"}],"wp:attachment":[{"href":"https:\/\/localdab.org\/index.php\/wp-json\/wp\/v2\/media?parent=2385"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}